KOMTEX-2WIRE-BK-AKB-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32, NOTIFICATION-TYPE FROM SNMPv2-SMI snmpTraps FROM SNMPv2-MIB TEXTUAL-CONVENTION FROM SNMPv2-TC; bkAKBModuleIdentity MODULE-IDENTITY LAST-UPDATED "201708310000Z" ORGANIZATION "OOO NPC 'Computer Techologies'" CONTACT-INFO "Web-site: www.http://censor-m.ru/ Emale: help@censor-m.ru" DESCRIPTION "Generic MIB for BK-AKB remote sensing and control" REVISION "201708310000Z" DESCRIPTION "SMIv2-style rewrite" ::= { bkAKB 900 } komtex OBJECT IDENTIFIER ::= { enterprises 35606 } devices OBJECT IDENTIFIER ::= { komtex 1 } bkAKB OBJECT IDENTIFIER ::= { devices 268 } info OBJECT IDENTIFIER ::= { bkAKB 1 } ports OBJECT IDENTIFIER ::= { bkAKB 2 } FixedPoint10 ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-1" STATUS current DESCRIPTION "Fixed-point value as Integer, 1 decimal gigits after point (i.e. value*10 rounded to Integer)" SYNTAX Integer32 FixedPoint1000 ::= TEXTUAL-CONVENTION DISPLAY-HINT "d-3" STATUS current DESCRIPTION "Fixed-point value as Integer, 3 decimal gigits after point (i.e. value*1000 rounded to Integer)" SYNTAX Integer32 bkAKBTable OBJECT-TYPE SYNTAX SEQUENCE OF BkAKBEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BK-AKB table" ::= { info 1 } bkAKBEntry OBJECT-TYPE SYNTAX BkAKBEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BK-AKB table row" INDEX { bkAKBDeviceSN } ::= { bkAKBTable 1 } BkAKBEntry ::= SEQUENCE { bkAKBDeviceSN Unsigned32, bkAKBDeviceCode Integer32, bkAKBDeviceName OCTET STRING } bkAKBDeviceSN OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Serial number of BK-AKB" ::= { bkAKBEntry 1 } bkAKBDeviceCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Device code of BK-AKB" ::= { bkAKBEntry 2 } bkAKBDeviceName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Device name of BK-AKB" ::= { bkAKBEntry 3 } akb1Table OBJECT-TYPE SYNTAX SEQUENCE OF Akb1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BK-AKB akb 1 signals table" ::= { ports 1 } akb1Entry OBJECT-TYPE SYNTAX Akb1Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BK-AKB signals table row" INDEX { akb1SN } ::= { akb1Table 1 } Akb1Entry ::= SEQUENCE { akb1SN Unsigned32, akb1Block1Current FixedPoint1000, akb1Block1Voltage FixedPoint10, akb1Block2Voltage FixedPoint10, akb1Block3Voltage FixedPoint10, akb1Block4Voltage FixedPoint10, akb1Block5Voltage FixedPoint10, akb1Block1Thermo FixedPoint10, akb1Block2Thermo FixedPoint10, akb1Block3Thermo FixedPoint10, akb1Block4Thermo FixedPoint10 } akb1SN OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Serial number of BK-AKB" ::= { akb1Entry 1 } akb1Block1Current OBJECT-TYPE SYNTAX FixedPoint1000 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 current value, with fractional part 1 digit after point, A" ::= { akb1Entry 2 } akb1Block1Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 1 voltage value, with fractional part 1 digit after point, V" ::= { akb1Entry 3 } akb1Block2Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 2 voltage value, with fractional part 1 digit after point, V" ::= { akb1Entry 4 } akb1Block3Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 3 voltage value, with fractional part 1 digit after point, V" ::= { akb1Entry 5 } akb1Block4Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 4 voltage value, with fractional part 1 digit after point, V" ::= { akb1Entry 6 } akb1Block5Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 5 voltage value, with fractional part 1 digit after point, V" ::= { akb1Entry 7 } akb1Block1Thermo OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 1 temperature value, with fractional part 1 digit after point, deg. C" ::= { akb1Entry 8 } akb1Block2Thermo OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 2 temperature value, with fractional part 1 digit after point, deg. C" ::= { akb1Entry 9 } akb1Block3Thermo OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 3 temperature value, with fractional part 1 digit after point, deg. C" ::= { akb1Entry 10 } akb1Block4Thermo OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 4 temperature value, with fractional part 1 digit after point, deg. C" ::= { akb1Entry 11 } akb2Table OBJECT-TYPE SYNTAX SEQUENCE OF Akb2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BK-AKB akb 2 signals table" ::= { ports 2 } akb2Entry OBJECT-TYPE SYNTAX Akb2Entry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BK-AKB signals table row" INDEX { akb2SN } ::= { akb2Table 1 } Akb2Entry ::= SEQUENCE { akb2SN Unsigned32, akb2Block1Current FixedPoint1000, akb2Block1Voltage FixedPoint10, akb2Block2Voltage FixedPoint10, akb2Block3Voltage FixedPoint10, akb2Block4Voltage FixedPoint10, akb2Block5Voltage FixedPoint10, akb2Block1Thermo FixedPoint10, akb2Block2Thermo FixedPoint10, akb2Block3Thermo FixedPoint10, akb2Block4Thermo FixedPoint10 } akb2SN OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Serial number of BK-AKB" ::= { akb2Entry 1 } akb2Block1Current OBJECT-TYPE SYNTAX FixedPoint1000 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 current value, with fractional part 1 digit after point, A" ::= { akb2Entry 2 } akb2Block1Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 1 voltage value, with fractional part 1 digit after point, V" ::= { akb2Entry 3 } akb2Block2Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 2 voltage value, with fractional part 1 digit after point, V" ::= { akb2Entry 4 } akb2Block3Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 3 voltage value, with fractional part 1 digit after point, V" ::= { akb2Entry 5 } akb2Block4Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 4 voltage value, with fractional part 1 digit after point, V" ::= { akb2Entry 6 } akb2Block5Voltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 5 voltage value, with fractional part 1 digit after point, V" ::= { akb2Entry 7 } akb2Block1Thermo OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 1 temperature value, with fractional part 1 digit after point, deg. C" ::= { akb2Entry 8 } akb2Block2Thermo OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 2 temperature value, with fractional part 1 digit after point, deg. C" ::= { akb2Entry 9 } akb2Block3Thermo OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 3 temperature value, with fractional part 1 digit after point, deg. C" ::= { akb2Entry 10 } akb2Block4Thermo OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB 1 monoblock 4 temperature value, with fractional part 1 digit after point, deg. C" ::= { akb2Entry 11 } commonTable OBJECT-TYPE SYNTAX SEQUENCE OF CommonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BK-AKB common signals table" ::= { ports 3 } commonEntry OBJECT-TYPE SYNTAX CommonEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "BK-AKB signals table row" INDEX { bkAKBSN } ::= { commonTable 1 } CommonEntry ::= SEQUENCE { bkAKBSN Unsigned32, akbVoltage FixedPoint10, akbRemainingTime Integer32 } bkAKBSN OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Serial number of BK-AKB" ::= { commonEntry 1 } akbVoltage OBJECT-TYPE SYNTAX FixedPoint10 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB voltage value, with fractional part 1 digit after point, V" ::= { commonEntry 2 } akbRemainingTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "BK-AKB remaining time of work, with fractional part 1 digit after point, sec" ::= { commonEntry 3 } END